Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
56352 | MANHATTAN/CDT COLE-FLEX |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
HUES | COLOR | BLACK |
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MOD BY COLOR |
FLEX | FLEXIBILITY | FLEXIBLE |
ABJH | TEMP RATING | -10.0 DEG CELSIUS AND 105.0 DEG CELSIUS |
MATL | MATERIAL | PLASTIC,POLYVINYL CHLORIDE,MIL-I-631,TYPE F,FORM U,SUBFORM UA,GRADE C,CLASS 1,CATEGORY 1 |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
AAGT | WALL THICKNESS | 0.010 INCHES MINIMUM AND 0.014 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ZZZT | NONDEFINITIVE SPEC/STD DATA | 1 CATEGORY AND 1 CLASS AND 24 AWG SIZE AND C GRADE AND U FORM AND UA SUBFORM AND F TYPE |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 800.0 VOLTS PER MIL /0.001 INCH/ |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
CQBC | MINIMUM TENSILE STRENGTH | 1800 POUNDS PER SQUARE INCH |
ADZC | ENVIRONMENTAL PROTECTION | MILDEW RESISTANT AND FLAME RESISTANT AND OIL RESISTANT |
AARX | INSIDE DIAMETER | 0.020 INCHES MINIMUM AND 0.027 INCHES MAXIMUM |